Proposed fitting function for the critical Casimir force on < sup > 4 < /sup > He film below the λ point

dc.contributor.author Biswas, Shyamal
dc.date.accessioned 2022-03-27T12:00:32Z
dc.date.available 2022-03-27T12:00:32Z
dc.date.issued 2010-07-01
dc.description.abstract We have extended the mean field calculations [9] of Zandi et al. (2007) and have obtained an approximate mathematical expression for the Casimir scaling function θ{symbol} (y), which if extrapolated to the domain π2 ≥ - y ≥ 0, becomes surprisingly similar to that obtained experimentally [16] by Ganshin et al. (2006). The extrapolated θ{symbol} (y) can be regarded as a proposed fitting function, that appears to agree better with the experiments [16] in D = 3, than the exact mean field results of Zandi et al. (2007) [9]. © 2010 Elsevier B.V. All rights reserved.
dc.identifier.citation Physica A: Statistical Mechanics and its Applications. v.389(13)
dc.identifier.issn 03784371
dc.identifier.uri 10.1016/j.physa.2010.03.018
dc.identifier.uri https://www.sciencedirect.com/science/article/abs/pii/S0378437110002220
dc.identifier.uri https://dspace.uohyd.ac.in/handle/1/15156
dc.subject Critical point phenomena
dc.title Proposed fitting function for the critical Casimir force on < sup > 4 < /sup > He film below the λ point
dc.type Journal. Article
dspace.entity.type
Files
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description: